9.8.3

XML restore

Note
Frequent use of "XML Restore" can reduce the service life of the optical reader
Note that each "XML Restore" performs write operations in Flash memory. If the "XML
Restore" function is used frequently, this can reduce the service life of the optical reader.
Disable import of the remote client IP address
If the remote client IP address currently set on the optical reader does not match the IP
address of the imported XML Restore file, remote client connection and data transfer are not
possible.
Ensure that the remote client IP address is not imported by disabling the "form-data" date in
the "XML Restore" file, "importremoteclientip".
Request
Stucture and properties of the request:
• URI: http://<Optical reader IP address>/xml/restore.cgi
e.g. http://192.168.0.42/xml/restore.cgi
• HTTP method: POST
• Content Type: "multipart/form-data;
boundary=[REMOTEXMLUPLOADPARA]\r\n"
POST data
Note
Notation
<xmlFile>
Corresponds to the string containing the contents of an "XML Backup" file.
<on|off>
• If the parameter group is to be imported, use the string "on"
• If the parameter group is not to be imported, use the string "off".
"[REMOTEXMLUPLOADPARA]
Content-Disposition: form-data; name="xmlfile"
Content-Type: text/xml
<xmlFile>
[REMOTEXMLUPLOADPARA]
Content-Disposition: form-data; name="importtcp"
SIMATIC MV500
Operating Instructions, 03/2021, C79000-G8976-C494-05
Process interfacing via an automation system (PLC, PC)
9.8 Remote client