Invacare 2G Tarsys Service Manual page 63

Table of Contents

Advertisement

5. Remove the shoulder bolt and locknut that secure the 10°/15° recline link to the front
pivot assembly. Refer to Detail "B".
6. Remove the recline link.
7. Reposition the recline link to the seat frame pin through the other mounting hole.
Refer to Detail "A" in FIGURE 6.7.
8. Secure the 10°/15° recline link to the seat frame pin with the washer and a new
retaining ring.
Be sure to use a new retaining ring that is not bent or damaged.
NOTE: When completed, verify that the retaining ring is fully seated in the groove in the pin.
9. Insert the existing shoulder bolt through the other mounting hole in the front pivot
assembly and then through the pivot hole in the recline link. Refer to Detail "B" in
FIGURE 6.7.
10. Securely tighten the locknut.
11. Repeat STEPS 4–10 for the opposite side.
12. Perform the post-service inspection. Refer to Post-Service Inspection Checklist on
page 21.
DETAIL "A"
*NOTE: Use
new retaining
ring.
*Retaining
Ring
Washer
Mounting Hole for
15° Seat Angle
NOTE: Drawing shows attachment for 15°
seat angle as an example.
FIGURE 6.7 Changing Seat Angle from 10° to 15° (or Vice Versa)
Part No 1114842
CAUTION
Pin
Mounting Hole for
10° Seat Angle
SECTION 6—SEAT ADJUSTMENTS
DETAIL "B"
10° and 15°
Recline Link
Shoulder
Bolt
Front Pivot
Assembly
Mounting Hole for
NOTE: Drawing shows attachment
for 15° seat angle as an example.
63
2G Tarsys®Powered Seating System
Locknut
Mounting Hole for
15° Seat Angle
10° Seat Angle

Advertisement

Table of Contents
loading

This manual is also suitable for:

2gt2gr2gtrTdx

Table of Contents