TROUBLESHOOTING
ALTERNATOR SYSTEM
TROUBLE
PROBA B L E CA USE
REMA RKS
i.
No alternator output
or
a.
Open
circuit.
a.
Check
continuity
low
charge
is indicated
of
the circuit.
b.
Circuit
breaker
b.
Check for short circuit
tripped.
and
reset
circuit breaker.
c.
Loose
or
improper
c.
Check
wiring diagram
connections.
for
proper
connections
and
tighten
all
con-
nections.
d.
Open
or
shorted
d.
Test resistance of the
field circuit in
field. Check field
alternator; defective
circuit connections;
rotor,
replace
alternator if
necessary.
e.
Brushes
not contact-
e.
Clean brushes and holders
ing slip-rings.
with
a
lint´•free,
dry
cloth, replace
weak
springs.
f.
Worn
or
broken
f.
Check brushes and
brushes.
replace
if
necessary.
g.
Open
current
limiter
g.
Check for shorted alter-
in
output line,
nator.
(Alternator
out-
put will
not
normally
be
sufficient
to
burn
out
the
current
limiter.)
h.
Engine
speed
too
h.
Increase
engine
rpm.
low.
i.
Defective
voltage
i.
Replace
voltage
regulator.
regulator.
j.
Defective loadmeter.
j.
Replace
loadmeter.
2.
Noisy
alternator.
a.
Worn
bearing.
a.
Replace
bearing.
b.
Shorted rectifier
b.
Replace
rectifier.
(magnetic
noise).
c.
Bent
or
broken fan.
c.
Replace
fan.
d.
Loose
rear
housing
or
d.
Tighten
rear
housing
improperly
installed
or
check
stater
for
stater.
proper
installation.
24-30-00
Page