Oxygen System - Raytheon BEECH BARON 58P Maintenance Manual

Table of Contents

Advertisement

BEECHCRAFT
BARON 58P AND 58TC
MAINTENANCE MANUAL
Circular
43.lj-lft
contains
the
When
ii!l'nc!
the
oxygen
system,
use
only
necessary
information.
MIL-0-27210
Aviator's
Breathing
Oxygen(l9,
Chart
207,
91-00-00).
To
pre-
The
oxygen
system
consists
of
a
supply
vent
overheating,
fill
the
oxygen
system
cyl
i
nder,
wi th
the
regulator
mounted
on
slowly
by
adjusting
the
recharging
rate
the
top
of
the
cylinder,
a
push-pull
con-
with the pressure
regulating
valve
on
the
trol
knob,
a
supply
pressure
gage
and
cart.
The
oxygen
cylinder
should
be filled
oxygen
outlets.
to
a
pressure
of
1800
+50
psi
at
a
tem-
perature
of
700F,
increased
by
3.5
psi
for
To
charge
the
oxygen
system,
gain
access
each
degree
above
700F,
or
decreased
by
to
the
oxygen
supply cylinder. (The cyl-
3.5
psi
for
each
degree
below
700F.
When
inder
is
located beneath the
pilot
s
seat
the
oxygen
system
is
properly
charged,
on
TJ-3
through T3-85,
except
TJ-82,
and
disconnect the
hose
from the
filler
port
on
TJ-82 and T3-86 and
after,
in
the
aft
and
replace
the
protective
cap.
If
at any
fuselage.
On TK-1 thru
TK-84,
the
cylinder
time,
in
the
process
of
or
is
located
in
the
nose
baggage
compart-
purging
the
system
or
replacing
the oxygen
ment;
on
TK-85
and
after,
it
is
located
cylinder,
it
becomes
necessary
to
in
the
aft
fuselage.)
Connect
the
oxygen
disconnet
a
fitting,
the
threads
should
recharge
service
cart
to
the service
port
be
treated
with
MIL-T-27730
of the
regulator.
tetrafluorethylene
tape
(Chart
201,
12-20-00).
The
system
should
then
be
WARNING
checked
for
leaks
with
MIL-L-25567
leak
testing
compound
(14,
Chart
207,
Keep
fires, cigarettes
and
sparks
91-00-00).
After
testing,
if
no
leaks
are
away
when
outlets
are
in
use.
found,´•wipe
the
sytem
clean and
dry.
Inspect
the
filler
connection
for
cleanliness
before
attaching
it
WARN ING
to
the
filler
port.
Keep
tools,
hands
and
components
clean,
as
Do
not
use
oxygen
intended
for
fire
or
explosion
may
occur
when
medical
purposes,
or
such
indus-
pure
oxygen
under
pressure
comes
trial
use
as
welding.
Such oxygen
in contact
with
organic
material
may
contain
moisture
that
could
such
as
grease
or
oil.
freeze the
valves
and lines of the
oxygen
system.
"END"
12-10-00
Page
205
A22
May
22/87

Hide quick links:

Advertisement

Table of Contents

Troubleshooting

loading

This manual is also suitable for:

Beech baron 58paBeech baron 58tcBeech baron 58ca

Table of Contents