2. Disconnect the connectors [1], Clamp [2].
• 12 Connectors [1]
• 1 Clamp [2]
3. Free the harness [1] from the hole [2] in the Low Voltage Power Supply Unit.
4. Remove the Low Voltage Power Supply Unit [1].
• 2 Screws [2]

Removing the Secondary Transfer High Voltage PCB

■ Preparation
1. Remove the Cassette Connector Cover.
2. Remove the Cover (Rear Lower).
3. Remove the Motor
Fan."Removing the Motor Fan" on page 283
12x
[1]
[2]
[1]
2x
285