The Itb Unit Cannot Be Removed Due To A Disengagement Error Of The Primary Transfer Roller - Canon imageRUNNER ADVANCE C3330 Series Service Manual

Hide thumbs Also See for imageRUNNER ADVANCE C3330 Series:
Table of Contents

Advertisement

[Stop positions and check items]
Items that can be checked differ depending on the position where paper stops.
Check for fold/skew/crease/operation check/jam/checking of image on ITB with reference to the table below.
No.
Stop position
0
Not forcibly stopped
20
Pre-registration (1st side)
21
Pre-registration (2nd side) *1
30
Pre-fixing (1st side)
31
Pre-fixing (2nd side) *1
32
Post-fixing (1st side)
33
Post-fixing (2nd side) *1
40
Second Delivery (1st side) *2
41
Second Delivery (2nd side)
*1, *2
70
Reverse position 1 *1, *4
71
Reverse position 2 *1, *3
72
Duplex standby position *1
99
Pre-fixing (1st side, when
checking the image)
*1: Paper is stopped when a duplex job is executed (paper is stopped after being reversed)
*2: Paper may not stop depending on the setting of delivery outlet (3 Way Unit-D1 should be installed)
*3: The size of paper should be the one that allows to pass the short path (e.g.: A4, LTR, etc.)
*4: The size of paper should be the one that can pass the long path (e.g.: A4R, LTRR; 3 Way Unit-D1 should be installed)
* This function can be used from MN-CON V06.xx and DC-CON V07.xx.
The ITB Unit Cannot Be Removed Due to a Disengagement Error of
the Primary Transfer Roller
Location
ITB Unit
Cause/Condition
When an unexpected situation or unexpected combination of conditions occurs, a Primary Transfer Roller disengagement
error may occur. This may result in the ITB Unit not being able to be removed from the host machine.
Field Remedy
Follow the procedure shown below to remove the ITB Unit from the host machine.
Bend
Skew
-
-
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
-
Yes
-
Yes
Yes
Yes
Yes
Yes
Yes
-
-
413
Wrinkle
Operation
check/Jam
-
-
-
Yes
-
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
-
Yes
-
Yes
-
Yes
-
Yes
-
Yes
-
-
6. Troubleshooting
Checking of the
image on the
ITB
-
-
-
Yes
Yes
Yes
Yes
-
-
-
-
-
Yes

Advertisement

Table of Contents
loading