Toro Reelmaster 6500-D Service Manual page 87

Hide thumbs Also See for Reelmaster 6500-D:
Table of Contents

Advertisement

1. Make sure hydraulic oil is at normal operating tem-
perature by operating the machine for approximately 10
minutes. Make sure the hydraulic tank is full.
2. Make sure machine is parked on a level surface with
the cutting units lowered and off. Make sure engine is off
and the parking brake is engaged.
3. Read Precautions for Hydraulic Testing.
Note: The reel motors are connected in series. To iso-
late a faulty motor, you may have to test all three motors
in the circuit by starting with the upstream motor first.
4. Disconnect the motor case drain hose (small diame-
ter hose) where it connects to traction unit (not at the mo-
tor). Put a steel cap on the fitting at the traction unit;
leave the case drain hose open (Fig. 20)
5. Disconnect hose from return of the motor to be
tested. Install tester in series with the motor and discon-
nected return hose. Make sure the flow control valve on
tester is fully open. (Fig. 20).
6. Set reel speed control to the full speed position.
Make sure Mow/Backlap valve is in the "Mow" position.
Note: Use a graduated container, special tool
TOR4077, to measure case drain leakage (Fig. 20).
CAUTION
Cutting unit reels will rotate when lowered with
Enable/Disable switch in ENABLE position.
Keep away from cutting units during test to pre-
vent personal injury from rotating reel blades. Do
not stand in front of the machine.
Reelmaster 6500-D/6700-D
7. Sit on seat and start the engine. Move throttle to full
speed (3200 RPM). Move "Enable/Disable" switch to
ENABLE. Move "Lower-Mow/Raise" lever forward to
engage cutting units.
8. While watching pressure gauge, slowly close flow
control valve on tester until a pressure of 1200 PSI is ob-
tained.
9. Have another person measure flow from the case
drain line for 15 seconds, then move the switch to DIS-
ABLE and stop the engine.
METER READING: 0.7 GPM or less at 1200 PSI.
10.Measure the amount of oil collected in the container.
Multiply the amount collected by 4 (to get gallons per
minute) or use the chart below. If flow exceeded .7 GPM,
the reel motor should be repaired or replaced.
11. If flow is less than .7 GPM, disconnect tester from
motor and hose. Reconnect hose to the reel motor. Re-
move plug from machine. Reconnect case drain hose to
the reel motor.
Page 4 - 45
Hydraulic System

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Reelmaster 6700-d038060380703808