25 ft- -lb
(33 N- -m)
48 to 60 in- -lb
(5.4 to 6.7 N- -m)
9
2
8
2
5
7
20 ft- -lb
(27 N- -m)
(Lift Manifold For RM6700--D Units With Serial No. Above 280000000)
1. Solenoid valve (S3)
2. Solenoid coil (8 used)
3. Solenoid coil
4. Solenoid valve (S2)
5. Solenoid blocking valve (6 used)
6. Flow control valve (5 used)
Note: The ports on the manifold(s) are marked for
easy identification of components. Example: S1 is a so-
lenoid valve and P3 is the gear pump connection port
(See Hydraulic Schematics to identify the function of the
hydraulic lines and cartridge valves at each port loca-
tion).
Hydraulic System
20 ft- -lb
(27 N- -m)
2
5
6
10
11
10 ft- -lb
(14 N- -m)
6
25 ft- -lb
(33 N- -m)
Figure 50
7. Flow control valve (2 used)
8. Solenoid coil spacer
9. Lift manifold block
10. Orifice (.063)
11. Straight fitting (3 used)
Page 4 -
20 ft- -lb
(27 N- -m)
1
2
16
2
13
3
4
9
15
10
11
12. NWD- -6 plug
13. Solenoid valve (S1)
14. Orifice (.100)
15. 90
16. Nut
NOTE: The lift control manifold shown in Figure 50
uses a zero leak plug (item 12). This plug has a tapered
sealing surface on the plug head that is designed to re-
sist vibration induced plug loosening. The zero leak plug
also has an o--ring to provide a secondary seal. If zero
leak plug removal is necessary, lightly rap the plug head
using a punch and hammer before using an allen
wrench to remove the plug: the impact will allow plug re-
moval with less chance of damage to the socket head of
the plug. When installing plug into the control manifold,
torque plug 25 ft- -lb (33 N- -m).
76.2
Rev. F
48 to 60 in- -lb
(5.4 to 6.7 N- -m)
20 ft- -lb
(27 N- -m)
25 ft- -lb
25 ft- -lb
(33 N- -m)
(33 N- -m)
12
14
11
UP
10 ft- -lb
(14 N- -m)
o
hydraulic fitting
Reelmaster 6500-D/6700-D