Toro Reelmaster 6500-D Service Manual page 119

Hide thumbs Also See for Reelmaster 6500-D:
Table of Contents

Advertisement

25 ft- -lb
(33 N- -m)
9
4
8
20 ft- -lb
12
(27 N- -m)
10 ft- -lb
(14 N- -m)
(Lift Manifold For RM6500--D Units With Serial No. Above 280000000)
1. Lift manifold block
2. Nut
3. NWD- -6 plug
4. Solenoid blocking valve (4 used)
5. Solenoid valve (S3)
6. Solenoid valve (S1)
Note: The ports on the manifold(s) are marked for
easy identification of components. Example: S1 is a so-
lenoid valve and P3 is the gear pump connection port
(See Hydraulic Schematics to identify the function of the
hydraulic lines and cartridge valves at each port loca-
tion).
Reelmaster 6500-D/6700-D
2
15
9
13
4
11
Figure 49
7. Solenoid valve (S2)
8. Flow control valve (2 used)
9. Solenoid coil (6 used)
10. Solenoid coil
11. Orifice (.063)
Page 4 -
16
9
9
9
6
5
4
20 ft- -lb
(27 N- -m)
1
UP
12. Straight fitting (2 used)
13. Flow control (3 used)
14. Orifice (.100)
15. Solenoid coil spacer
16. Nut
NOTE: The lift control manifold shown in Figure 49
uses a zero leak plug (item 3). This plug has a tapered
sealing surface on the plug head that is designed to re-
sist vibration induced plug loosening. The zero leak plug
also has an o--ring to provide a secondary seal. If zero
leak plug removal is necessary, lightly rap the plug head
using a punch and hammer before using an allen
wrench to remove the plug: the impact will allow plug re-
moval with less chance of damage to the socket head of
the plug. When installing plug into the control manifold,
torque plug 25 ft- -lb (33 N- -m).
76.1
Rev. F
48 to 60 in- -lb
(5.4 to 6.7 N- -m)
2
10
7
20 ft- -lb
(27 N- -m)
25 ft- -lb
(33 N- -m)
3
10 ft- -lb
(14 N- -m)
14
12
Hydraulic System

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Reelmaster 6700-d038060380703808