MODE 020
Factory setting bit : 0 1 0 0 0 0 0 0 (Hex : 40)
Bit
Feature
7
Displays # of reports.
6
Trace protocol.
5
Display number of error
lines/transmission
speed.
4
Select monitor interval
for line.
3
Display error codes.
(Panel, report)
210
MODE 021
Factory setting bit : 0 0 0 0 0 0 0 0 (Hex : 00)
Bit
Feature
765
43
2
Display symbol rate.
1
Observe EQM.
0
Observe probing information.
Logic
Meaning
0
No
1
Yes
0
No
1
Yes
0
No
1
Yes
0
Phase A
1
All phases
0
No
1
Yes
000
Fixed to "000"
Logic
Meaning
00000
Fixed to "00000"
0
No
1
Yes
0
No
1
Yes
0
No
1
Yes
S-46
Description
"Yes" displays # of pages on
phone line in addition to
ordinary # of papers.
"Yes" prints result of protocol
trace after completing
communication. If next
communication is proceeded
before this printing, information
on previous communication
protocol will be deleted.
"Yes" displays # of error lines/
transmission speed on panel
and outputs port for auto
checking.
Specifies interval for monitoring
phone lines for G3
communication.
"Yes" displays error codes (6
digit) on panel and in report.
Description
Symbol rates are 2400/
2743/2800/3000/3200/
3429. Rate of 2743 is not
actually used.
Check modem & line
statuses
Check modem & line
statuses