MODE 230
Factory setting bit : 0 0 0 0 0 1 0 1 (Hex : 05)
Bit
76543210 DP steady current time 1.
(PSTN2)
MODE 231
Factory setting bit : 0 0 0 0 0 0 1 0 (Hex : 02)
Bit
76543210 DP steady current time 2.
(PSTN2)
MODE 232
Factory setting bit : 0 1 0 0 0 0 0 0 (Hex : 40)
Bit
Feature
76
Select DP make rate.
(PSTN2)
543210
Feature
00000000
00000001
00000101 50 msec
11111111
Feature
00000000
00000001
00000010 200 msec
11111111
S-89
Logic
Meaning
0 msec
10 msec
2550 msec
Logic
Meaning
0 msec
10 msec
2550 msec
Logic
Meaning
00
33 %
01
40 %
Others
Not available
000000
Fixed to "000000"
Description
Set interval from S relay
ON to DP photo coupler
ON.
Valid only when "DP/PB
switch (MODE 011 Bit
5)" selects "DP".
Description
Set interval from DP
photo coupler OFF to S
relay OFF.
Valid only when "DP/PB
switch (MODE 011 Bit
5)" selects "DP".
Description