Minolta Di251f Service Manual page 132

Hide thumbs Also See for Di251f:
Table of Contents

Advertisement

MODE 210
Factory setting bit : 0 0 0 0 0 1 0 1 (Hex : 05)
Bit
76543210 DP steady current time 1.
(PSTN1)
MODE 211
Factory setting bit : 0 0 0 0 1 1 0 0 (Hex : 0C)
Bit
76543210 DP steady current time 2.
(PSTN1)
MODE 212
Factory setting bit : 0 1 0 0 0 0 0 0 (Hex : 40)
Bit
Feature
76
Select DP make rate.
(PSTN1)
543210
Feature
00000000
00000001
00000101 50 msec
11111111
Feature
00000000
00000001
00001100 120 msec
11111111
S-88
Logic
Meaning
0 msec
10 msec
2550 msec
Logic
Meaning
0 msec
10 msec
2550 msec
Logic
Meaning
00
33 %
01
40 %
Others
Not available
000000
Fixed to "000000"
Description
Set interval from S relay
ON to DP photo coupler
ON.
Valid only when "DP/PB
switch (MODE 006 Bit
5)" selects "DP."
Description
Set interval from DP
photo coupler OFF to S
relay OFF.
Valid only when "DP/PB
switch (MODE 006 Bit
5)" selects "DP."
Description

Advertisement

Table of Contents
loading

This manual is also suitable for:

Di351f

Table of Contents