Minolta Di251f Service Manual page 109

Hide thumbs Also See for Di251f:
Table of Contents

Advertisement

MODE 054
Factory setting bit : 0 0 0 0 1 0 1 0 (Hex : 0A)
Bit
Feature
7654
3
Control history of V.34 auto
dialing.
2
Modulation method for V.34
manual, nonstorage TX.
1
Modulation method for V.34
polling TX document.
0
Modulation method for V.34
manual RX.
MODE 055
Factory setting bit : 0 0 0 0 0 0 0 0 (Hex : 00)
Bit
Feature
7
Set transmission level
to -8 dBm or more.
6543
210
Logic
Meaning
0000
Fixed to "0000"
0
1
0
V.17
1
V.34
0
V.17
1
V.34
0
V.17
1
V.34
Logic
Meaning
0
prohibited
1
Permitted
0000000
Fixed to "0000000"
S-65
Description
No
Valid only when a receiver
system has V.34
Yes
modulation.
Description
By setting to "Permitted", bits 7 to
4 of MODE 085 and MODE 115
that specify the transmission level
can be set to 0000 (-1 dBm) to
0111 (-8 dBm). Setting of these
bits is normally prohibited.
(The setting is common to MODE
085 and MODE 115.)

Advertisement