MODE 097
Factory setting bit : 0 0 0 1 0 1 0 0 (Hex : 14)
Bit
Feature
7
Attenuate TCF/NTCF
sending level. (PSTN1)
6
Attenuate V17/V33/V29
sending level. (PSTN1)
5
432 Select V.34 symbol rate.
(PSTN1)
10
Logic
Meaning
0
No
1
Yes –3 dB
0
No
1
Yes –3 dB
0
Fixed to "0"
000
2400 Sym/S
001
Not available
010
2800 Sym/S
011
3000 Sym/S
100
3200 Sym/S
101
3429 Sym/S
Others Not available
00
Fixed to "00"
S-73
Description
Specifies whether sending level
of TCF and NTCF will be
attenuated. For V33/V29, level
of attenuation is determined by
MODE 085 Bit 7-4 and MODE
097 Bit 6. Otherwise, level of
attenuation is determined by
MODE 085 Bit 7-4.
Specifies whether sending level
of V17/V33/V29 will be
attenuated. Level of attenuation
is determined by MODE 085 Bit
7-4 and MODE 097 Bit 6.