MODE 005
Factory setting bit : 0 0 1 0 0 0 0 0 (Hex : 23)
Bit
Feature
7654 Select number of redialing 1.
(Number of auto redialing at
1st stage)
3210 Select number of redialing 2.
(Number of auto redialing at
the 2nd stage)
Note
• If the first stage sets [0000], the system proceeds to the second stage without the first
stage after 10 minutes.
• If the first and second stages set [0000], the auto redialing function will not be performed.
Logic
Meaning
0000
0
0001
1
0010
2
0011
3
0100
4
0101
5
0110
6
0111
7
1000
8
1001
9
1010
10
1011
11
1100
12
1101
13
1110
14
1111
15
0000
0
0001
1
0010
2
0011
3
0100
4
0101
5
0110
6
0111
7
1000
8
1001
9
1010
10
1011
11
1100
12
1101
13
1110
14
1111
15
S-37
Description
Specifies the number of
redialing with the interval
specified by "Select
redialing interval 1 (MODE
042 Bit 7-4)."
Once redialing set by
"Select number of redialing
1 (MODE 005 Bit 7-4)", the
system redials the number
of times specified by this
soft switch.
Redialing interval follows
"Select redialing interval 2
(MODE 042 Bit 3-0)" at the
first time and then follows
"Select redialing interval 1
(MODE 042 Bit 7-4)" from
the second time.