OneStor® SP-3584 Installation & User Guide
• Allow 15 seconds between turning the PSU off and back on again.
• Allow 15 seconds between turning one PSU in the system on and the other PSU off.
• Never turn off a PSU whilst any amber LED is lit on the partner PSU.
• The enclosure must be left in a powered state for 30 seconds following resumption from standby
Figure 4–1

4.3 Ops Panel LEDs

Table 4–1
Please refer to section
Table 4–1
LED
Power On/Standby
Module Fault
Logical Status
Drawer 1/2 Fault
30
before the enclosure can be placed into standby again.
PSU Power Switch and LEDs
describes the ops panel LED fault and status conditions.
on page 35
Ops Panel LEDs
Status
Constant green: power is on
Constant amber: system is in standby (not operational)
Constant or flashing amber: fault
Constant or flashing amber: fault
Constant amber: fault in drive, cable or sideplane for specified drawer
for details of any fault indication.
Figure 4–2
shows the panel layout.