Product Manual Cheetah 15K.7 SAS Standard models Self-Encrypting Drive models ST3600057SS ST3600957SS ST3450857SS ST3450757SS ST3300657SS ST3300557SS SED FIPS 140-2 models ST3600857SS ST3450657SS ST3300457SS 100516226 Rev. C September 2010...
Page 2
States and/or other countries. All other trademarks or registered trademarks are the property of their respective owners. No part of this publication may be reproduced in any form without written permission of Seagate Technology LLC. Call 877-PUB-TEK1(877-782-8651) to request permission.
Authorized Service Centers For information regarding Warranty Support, visit http://www.seagate.com/www/en-us/support/warranty_&_returns_assistance For information regarding Data Recovery Services, visit http://www.i365.com For Seagate OEM & Distribution partner portal, visit https://direct.seagate.com/portal/system For Seagate reseller portal, visit http://spp.seagate.com Cheetah 15K.7 SAS Product Manual, Rev. C...
LLC, Cheetah SAS (Serial Attached SCSI) disk drives. Cheetah 15K.7 drives support the SAS Protocol specifications to the extent described in this manual. The SAS Interface Manual (part number 100293071) describes the general SAS characteristics of Cheetah 15K.7 and other Seagate SAS drives. The Self-Encrypting Drive (SED) Users Guide, part number 100515636 describes the interface, general operation and security features available on SED drives.
Section 11.3. Standards The Cheetah 15K.7 SAS family complies with Seagate standards as noted in the appropriate sections of this manual and the Seagate SAS Interface Manual, part number 100293071. The drives are recognized in accordance with UL 60950-1 and CSA 60950-1 as tested by UL and EN60950-1 as tested by TUV.
Lead (Pb), in electronic products effective July 2006. A number of parts and materials in Seagate products are procured from external suppliers. We rely on the rep- resentations of our suppliers regarding the presence of RoHS substances in these parts and materials. Our...
Seagate also has internal systems in place to ensure ongoing compliance with the RoHS Directive and all laws and regulations which restrict chemical content in electronic products. These systems include standard operat- ing procedures that ensure that restricted substances are not utilized in our manufacturing operations, labora- tory analytical validation testing, and an internal auditing process to ensure that all standard operating procedures are complied with.
Opening the HDA for any reason voids your warranty. Cheetah 15K.7 drives use a dedicated landing zone at the innermost radius of the media to eliminate the pos- sibility of destroying or degrading data by landing in the data zone. The heads automatically go to the landing zone when power is removed from the drive.
• Drive Self Test • Background Media Scan • Power Save Cheetah 15K.7 SAS SED models have the following additional features: • Automatic data encryption/decryption on all writes and reads to and from the media • Controlled access • Random number generator •...
Seagate designs specify capacity points at certain block sizes that Seagate guarantees current and future products will meet. We recommend customers use this capacity in their project planning, as it ensures a stable operating point with backward and forward compatibility from generation to generation.
Full stroke Typical Typical access times are measured under nominal conditions of temperature, voltage, and horizontal orientation as measured on a representative sample of drives. Access to data = access time + latency time. Cheetah 15K.7 SAS Product Manual, Rev. C...
After receiving a START STOP UNIT command with the START bit equal to 1, the drive waits for a NOTIFY (ENABLE SPINUP) primitive. After receiving a NOTIFY (ENABLE SPINUP) primitive through either port, the drive becomes ready for normal operations within 20 seconds (excluding the error recovery procedure). Cheetah 15K.7 SAS Product Manual, Rev. C...
Mode Select command (bytes 14 and 15) does not set up a new segment size. If the STRICT bit in Mode page 00h (byte 2, bit 1) is set to one, the drive responds as it does for any attempt to change an unchangeable parameter. Cheetah 15K.7 SAS Product Manual, Rev. C...
When prefetch (read look-ahead) is enabled (enabled by DRA = 0), the drive enables prefetch of contiguous blocks from the disk when it senses that a prefetch hit will likely occur. The drive disables prefetch when it decides that a prefetch hit is not likely to occur. Cheetah 15K.7 SAS Product Manual, Rev. C...
Unrecoverable Data Errors (Sense Key = 03h) are specified at less than 1 sector in error per 10 bits trans- ferred. Unrecoverable Data Errors resulting from the same cause are treated as 1 error for that block. Cheetah 15K.7 SAS Product Manual, Rev. C...
Caution. The drive motor must come to a complete stop prior to changing the plane of operation. This time is required to insure data integrity. Cheetah 15K.7 SAS Product Manual, Rev. C...
There is a separate Failure History Counter for each attribute. 6.2.5 Thermal monitor Cheetah 15K.7 drives implement a temperature warning system which: 1. Signals the host if the temperature exceeds a value which would threaten the drive. 2. Signals the host if the temperature exceeds a user-specified value.
DST. It is the responsibility of the host application to determine the “not ready” cause. While not technically part of DST, a Not Ready condition also qualifies the drive to be returned to Seagate as a failed drive.
Page 24
The drive will report the failure condition and LBA (if applicable) in the Self-test Results Log parameter. The Sense key, ASC, ASCQ, and FRU are used to report the failure condition. Cheetah 15K.7 SAS Product Manual, Rev. C...
Seagate’s option and at no charge to the customer, if returned by customer at customer’s expense to Seagate’s designated facility in accordance with Seagate’s warranty procedure.
ASIC is enabled and functional in the SED models. This represents a small additional drain on the 5V supply of about 30mA and a commensurate increase of about 150mW in power consumption. There is no additional drain on the 12V supply. Cheetah 15K.7 SAS Product Manual, Rev. C...
Page 27
Maximum DC (peak) 3σ 1.40 1.26 1.46 1.24 Peak operating current (sequential write): Typical DC [1][6] 0.93 0.83 0.94 0.83 Maximum DC 3σ 1.00 0.84 1.02 0.85 Maximum DC (peak) 3σ 1.30 1.24 1.30 1.26 Cheetah 15K.7 SAS Product Manual, Rev. C...
Page 28
Maximum DC (peak) 3σ 1.36 1.10 1.44 1.10 Peak operating current (sequential write): Typical DC [1][6] 0.95 0.69 0.98 0.67 Maximum DC 3σ 0.99 0.70 1.02 0.68 Maximum DC (peak) 3σ 1.26 1.10 1.30 1.12 Cheetah 15K.7 SAS Product Manual, Rev. C...
Page 29
This condition occurs after OOB and Speed Negotiation completes but before the drive has received the Notify Spinup primitive. See paragraph 7.2.1, "Conducted noise immunity." Specified voltage tolerance includes ripple, noise, and transient response. Cheetah 15K.7 SAS Product Manual, Rev. C...
7.2.3 Current profiles The +12V and +5V current profiles are shown below in the following figures. Note: All times and currents are typical. See Tables 13, 14, and 15 for maximum current requirements. Cheetah 15K.7 SAS Product Manual, Rev. C...
Page 31
Figure 1. Typical 600GB current profiles Figure 2. Typical 450GB current profiles Cheetah 15K.7 SAS Product Manual, Rev. C...
Page 32
Figure 3. Typical 300GB current profiles Cheetah 15K.7 SAS Product Manual, Rev. C...
+12 volt current, and total watts on the vertical axis. To calculate BTUs per hour, multiply watts by 3.4123. Figure 4. ST3600057SS DC current and power vs. input/output operations per second Cheetah 15K.7 SAS Product Manual, Rev. C...
Page 34
+12 volt current, and total watts on the vertical axis. To calculate BTUs per hour, multiply watts by 3.4123. Figure 5. ST3450857SS DC current and power vs. input/output operations per second Cheetah 15K.7 SAS Product Manual, Rev. C...
To confirm that the required cooling for the electronics and HDA case is provided, place the drive in its final mechanical configuration, perform random write/read operations and measure the HDA case temperature after it has stabilized. Cheetah 15K.7 SAS Product Manual, Rev. C...
Non-operating –40° to 158°F (–40° to 70°C) package ambient with a maximum gradient of 86°F (30°C) per hour. This specification assumes that the drive is packaged in the shipping container designed by Seagate for use with drive. HDA Temp.
Page 37
36 in (914 mm) Drives packaged in single or multipacks with a gross weight of 20 pounds (8.95 kg) or less by Seagate for general freight shipment shall withstand a drop test from 48 inches (1,070 mm) against a concrete floor or equivalent.
Page 38
Specified operational performance will continue when normal operating vibration levels are resumed. This assumes system recovery routines are available. Operating abnormal translational random flat profile 5 – 500 Hz 0.75 G (0 to peak) 10 - 300 Hz 0.0029 G c. Non-operating Cheetah 15K.7 SAS Product Manual, Rev. C...
There will not be any discrete tones more than 10 dB above the masking noise on typical drives when mea- sured according to Seagate specification 30553-001. There will not be any tones more than 24 dB above the masking noise on any drive.
(CSPs) within the module, or pick-resistant locks on covers or doors to protect against unauthorized physical access. Figure 10. Example of FIPS tamper evidence labels. Does not represent actual drive. Cheetah 15K.7 SAS Product Manual, Rev. C...
(TCG) Enterprise Storage Specifications as detailed in Section 3.4. The Trusted Computing Group (TCG) is an organization sponsored and operated by companies in the com- puter, storage and digital communications industry. Seagate’s SED models comply with the standards pub- lished by the TCG.
Authenticated firmware download In addition to providing a locking mechanism to prevent unwanted firmware download attempts, the drive also only accepts download files which have been cryptographically signed by the appropriate Seagate Design Center. Three conditions must be met before the drive will allow the download operation: 1.
The SED models support the following two commands in addition to the commands supported by the standard (non-SED) models as listed in Table 19: • Security Protocol Out (B5h) • Security Protocol In (A2h) Cheetah 15K.7 SAS Product Manual, Rev. C...
10.0 Defect and error management Seagate continues to use innovative technologies to manage defects and errors. These technologies are designed to increase data integrity, perform drive self-maintenance, and validate proper drive operation. SCSI defect and error management involves drive internal defect/error management and SAS system error considerations (errors in communications between the initiator and the drive).
Page 46
When the RC bit is one, reallocations are disabled even if the ARRE or AWRE bits are one. The drive will still perform data recovery actions within the limits defined by the Read Retry Count, Write Retry Count, and Recovery Time Limit parameters. However, the drive does not report any unrecovered errors Cheetah 15K.7 SAS Product Manual, Rev. C...
On regular duty drives, if the host system makes use of the BMS Log Page, it can avoid placing data in suspect locations on the media. Unreadable and recovered error sites will be logged or reallocated per ARRE/AWRE settings. Cheetah 15K.7 SAS Product Manual, Rev. C...
DAR is most effective when AWRE and ARRE are enabled—this is the default setting from the Seagate factory. With AWRE and ARRE disabled DAR is unable to reallocate the failing location and will report an error sense code indicating that a write command is being attempted to a previously failing location.
11.0 Installation Cheetah 15K.7 disk drive installation is a plug-and-play process. There are no jumpers, switches, or termina- tors on the drive. SAS drives are designed to be used in a host system that provides a SAS-compatible backplane with bays designed to accommodate the drive.
Increased radiated emissions may result if you do not provide the maximum surface area ground connection between system ground and drive ground. This is the system designer’s and integrator’s responsibility. Cheetah 15K.7 SAS Product Manual, Rev. C...
12.0 Interface requirements This section partially describes the interface requirements as implemented on Cheetah 15K.7 drives. Addi- tional information is provided in the SAS Interface Manual (part number 100293071). 12.1 SAS features This section lists the SAS-specific features supported by Cheetah 15K.7 drives.
12.2 Dual port support Cheetah 15K.7 SAS drives have two independent ports. These ports may be connected in the same or differ- ent SCSI domains. Each drive port has a unique SAS address. The two ports have the capability of independent port clocking (e.g. both ports can run at 6Gbit/sec or the first port can run at 6Gbit/sec while the second port runs at 3Gbit/sec.) The supported link rates are 1.5, 3.0, or 6.0...
Page 53
Table 19: Commands supported by Cheetah 15K.6 SAS family drives (continued) Command name Command code Supported TSD bit ETC bit TMC bit LP bit Log Sense Application Client Log page (0Fh) Buffer Over-run/Under-run page (01h) Cache Statistics page (37h) Factory Log page (3Eh)
Page 54
Table 19: Commands supported by Cheetah 15K.6 SAS family drives (continued) Command name Command code Supported Mode Sense (10) (same pages as Mode Sense 1Ah) Prefetch Read Read Buffer (modes 0, 2, 3, Ah and Bh supported) Read Capacity Read Defect Data (10)
Page 55
XDRead XDWrite XPWrite Cheetah 15K.7 drives can format to 512, 520, 524, or 528 bytes per logical block. Warning. Power loss during flash programming can result in firmware corruption. This usually makes the drive inoperable. Reference Mode Sense command 1Ah for mode pages supported.
Four ASCII digits representing the last four digits of the product firmware release number. Eight ASCII digits representing the eight digits of the product serial number. Bytes 18 through 26 reflect model of drive. The table above shows the hex values for Model ST3600057SS. Cheetah 15K.7 SAS Product Manual, Rev. C...
SCSI implementation (see the SAS Interface Manual ). Definitions: DEF = Default value. Standard OEM drives are shipped configured this way. CHG = Changeable bits; indicates if default value is changeable. Cheetah 15K.7 SAS Product Manual, Rev. C...
Reporting actual retry count in Extended Sense bytes 15, 16, and 17 Adaptive caching SMP = 1 in Mode Select command needed to save RPL and rotational offset bytes Table 22: Miscellaneous status Supported Status Good Check condition Condition met/good Busy Cheetah 15K.7 SAS Product Manual, Rev. C...
Figure 12 shows the location of the SAS device connector J1. Figures 13 and 14 provide the dimensions of the SAS device. Details of the physical, electrical, and logical characteristics are provided within this section. The operational aspects of Seagate’s SAS drives are provided in the SAS Interface Manual.. SAS Interface connector Figure 12.
Page 65
0.08 (4X) 0.30 0.05 (4X) SEE Detail1 33.43 0.05 15.875 15.875 1.27 (14X) 1.27 (6X) 0.84 0.05 (22X) 5.08 0.15 B 4.90 0.08 0.35MIN C OF DATUM B Figure 13. SAS connector dimensions Cheetah 15K.7 SAS Product Manual, Rev. C...
This section defines physical interface connector. 12.4.3 Connector requirements The SAS connector on the drive complies with SFF-8482. Contact your preferred connector manufacturer for mating part information. The SAS device connector is illustrated in Figures 13 and 14. Cheetah 15K.7 SAS Product Manual, Rev. C...
Diff output pair Ground S13* +Port B_out 12 Volts charge Port B Ground P14* 12 Volts P15* 12 Volts * - Short pin to support hot plugging NC - No connection in the drive. Cheetah 15K.7 SAS Product Manual, Rev. C...
Spun up and activity (command executing) Spinning up or down Blinks steadily (50% on and 50% off, 0.5 seconds on and off for 0.5 seconds) Format in progress Toggles on/off Write Same command in progress Toggles on/off Cheetah 15K.7 SAS Product Manual, Rev. C...
For more information about the Phy, Link, Transport, and Applications layers of the SAS interface, refer to the Seagate SAS Interface Manual, part number 100293071. For more information about the SCSI commands used by Seagate SAS drives, refer to the Seagate SCSI Commands Reference Manual, part number 100293068.
Page 70
Cheetah 15K.7 SAS Product Manual, Rev. C...
Page 71
BMS 41 DEK 36 buffer description 6 data 7 DFE 63 space 11 dimensions 34 busy status 57 disc rotation speed 9 drive 33 drive characteristics 9 cache operation 11 Drive Locking 37 Cheetah 15K.7 SAS Product Manual, Rev. C...
Page 72
44 Adaptive caching 57 Asynchronous event notification 57 Automatic contingent allegiance 57 HDA 43 Deferred error handling 57 head and disc assembly. See HDA Parameter rounding 57 heads Queue tagging 57 Cheetah 15K.7 SAS Product Manual, Rev. C...
Page 73
24 task management functions 45 performance characteristics SAS documents 5 detailed 9 SAS Interface Manual 3 general 10 SCSI interface performance degradation 31 commands supported 46 performance highlights 7 Secure ID 36 Cheetah 15K.7 SAS Product Manual, Rev. C...
Page 74
45 task management response codes 45 Function complete 00 45 Function not supported 05 45 Function reject 04 45 task set full status 58 TCG 36 technical support services 1 temperature 29 Cheetah 15K.7 SAS Product Manual, Rev. C...
Page 76
Seagate Technology LLC 920 Disc Drive, Scotts Valley, California 95066-4544, USA Publication Number: 100516226, Rev. C...