Index Sensor Removal; Installing The Optional Full-Height Front Panel; Figure 35: Index Sensor Adjustment/Removal - Seagate ST212 Product Manual

Table of Contents

Advertisement

9.3.3
INDEX SENSOR REMOVAL
Required Tools: T-lOTorx driver or standard blade screwdriver, 0.030" shim
1.
Remove the Main Control PCB. See
Section 9.3.1.
2. Disconnect the Front Panel LED. See
Figure 35.
3. Remove the sensor bracket mounting screw.
4. To install replacement, apply Loctite to the first three threads of the mount-
ing screw. Position the sensor, clamp and screw, but do not tighten.
5. Rotate the spindle motor clockwise until the silver tab aligns with the sensor.
6. Using the shim, verify that the gap is
.030'~
Tighten the screw.
'l!!"-...... --,MOUNTING
SCREW
i::z:::,...J.J--=~--
CLAMP
!.-Q'#---\--INDEX
SENSOR
TAB
(see notes
4-5)
9.3.4
INSTALLING THE OPTIONAL FULL-HEIGHT FRONT PANEL
Required Tools: T-IO Torx driver
Depending on how the unit was shipped from the factory, the unit may have
a half-height Front Panel already installed. To remove:
1.
Remove the Main Control PCB. See
Section 9.3.1.
2. Disconnect the LED. Refer to
Figure 34.
3. Remove the two mounting screws.
4. Reverse the procedure to install the replacement coyer.
FIGURE 35:
Index Sensor
AdjustmentiRemoval
38
ST212 PRODUCT MANUAL/Rev. B

Advertisement

Table of Contents
loading

Table of Contents