Do one of the following:
If you want to update the base IO flash memory, select YES to install the update. When
you choose Yes, a screen is displayed that indicates the flash memory is being updated
(Figure 80). After the update is completed, the Dome Information screen is redisplayed.
If you do not want to update the base IO flash memory, select NO to cancel the flash
updating process and return to the Dome Information screen.

Using the Calibration Screen

(Indoor and outdoor domes only) Calibration refers to using the configuration utility to define
a zero reference point (or target) from which all other camera targets will be referenced when a
dome is replaced on a base.
During calibration, the replacement camera is pointed at the desired target, which is the first
object the dome being replaced was set to and whose position was initially recorded in the base
memory. This object becomes the calibration reference point for the new dome camera. This
should be a permanent object that will not or cannot be moved, such as a door, and its position
should be written down for future reference.
SPEEDDOME ULTRA 8 CONFIGURATION UTILITY
OPERATOR'S GUIDE
Note:
This feature is only applicable to the Indoor Housing IO board (P/N
03120-3006-01) and the Outdoor Ho using IO board (P/N 0311-0124-xx).
Figure 80. Initializing base IO flash memory screen
Init IO Flash Memory!
Initializing
Please Wait
Note:
This procedure is only performed when an installed camera dome is
replaced by another dome in an existing base. The new dome then can be
calibrated to conform with the data already stored in the dome base.
91 of 140
8200-0600-01, REV. B