Water connections

Fig.41
Connecting the "heating circuit flow"
pipe
2
7609474 - v02 - 04092014
6. Remove the detachable panel if necessary.
MW-3000026-01

6.3.1 Connection of the heating circuit

Abide by the mountings shown in the hydraulic diagrams.
1. Remove the anti-dust plug located on the boiler's "heating flow" out­
2. Connect the "heating circuit flow" pipe to the boiler's "heating flow"
1
S S ee
The disassembly instructions can be found on the detachable pan­
el.
See
Connecting diagrams, page 33.
Caution
The heating pipe must be mounted in accordance with the provi­
sions applicable.
If installing isolation valves, position the fill/drain valve and the
expansion vessel between the isolation valves and the boiler.
Always install a safety valve calibrated to 4 bar on the heating
circuit. The safety valve can be connected to a venting pot. The
safety valve must not be used to drain the heating circuit.
See
In the case of an assembly with a low-loss header, use the as­
sembly instructions for the low-loss header.
If using a cascade kit, use the assembly instructions for the cas­
cade kit.
Note
The pipes are not provided.