6 Installation
Fig.59
1 boiler + 1 direct circuit + domestic hot water tank
34
26
11
11 Heating pump
21 Outside temperature sensor
26 DHW load pump
33 Domestic hot water temperature sensor
Fig.60
1 boiler + 1 direct circuit + 1 underfloor heating circuit + domestic hot water tank
34
26
11
2 Heating pump
11 Heating pump
21 Outside temperature sensor
26 DHW load pump
33 Domestic hot water temperature sensor
52
6 6 .6.7 Electrical connection: 1 boiler + 1 direct circuit + domestic
hot water tank
4
3
2
1
6.6.8 Electrical connection: 1 boiler + 1 direct circuit + 1 under
floor heating circuit + domestic hot water tank
158
AVS75
4
117
3
2
2
1
38
34 Primary pump
38 Remote control with or without room temperature
sensor
38
44
34 Primary pump
38 Remote control with or without room temperature
sensor
44 65°C safety thermostat with manual reset for under
floor heating (DTU 65.8, NF P52-303-1)
MW-3000114-01
21
1 2 3
MW-3000115-01
7609474 - v02 - 04092014
21
33
38
1 2 3
33
38
38
1 2 3