onboard clock, the generation resumes as soon as the pause trigger is
deasserted, as shown in Figure 5-5.
If you are using any signal other than the onboard clock as the source of
your sample clock, the generation resumes as soon as the pause trigger is
deasserted and another edge of the sample clock is received, as shown in
Figure 5-6.

Using a Digital Source

To use AO Pause Trigger, specify a source and a polarity. The source can
be one of the following signals:
© National Instruments
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Pause Trigger
Sample Clock
Figure 5-5. AO Pause Trigger with the Onboard Clock Source
Pause Trigger
Sample Clock
Figure 5-6. AO PauseTrigger with Other Signal Source
PFI <0..15>
RTSI <0..7>
PXI_STAR
PXIe-DSTAR<A,B>
Counter n Internal Output
Counter n Gate
AI Pause Trigger (ai/PauseTrigger)