Clearances; Mantel Requirements; Hearth Requirements; Facing Requirements - Lopi Yankee Bay Instruction Manual

Pellet insert
Hide thumbs Also See for Yankee Bay:
Table of Contents

Advertisement

1 0

Clearances

Insert must be placed so that no combustibles are within, or can swing within (e.g. drapes, doors),
36" of the front of the heater.
Insert must be placed a minimum 8-3/4" from
a side wall (or combustible protruding more
than 3/4").

Mantel Requirements

The mantel must meet the requirements
shown in the illustration to the right.

Hearth Requirements

The non-combustible hearth must extend 6"
to the front and sides of the firebox opening
(you must open the door to measure).

Facing Requirements

The non-combustible facing must extend 7"
to the side and 6" above the hopper lid.

Placing the Insert

The insert must be placed within an
undamaged masonry or factory built (metal)
fireplace. Loose bricks or other damage must
be fixed. Clean the fireplace before
installing.
Side Wall
© Travis Industries
Installation
Min. 8-3/4"
The mantel must fall
within this shaded area
(or above). Maximum
mantel depth is 12".
Apply the "This fireplace has been
altered..." sticker to the fireplace. You
may wish to place it in a location where it
will be covered by the surround panels.
13-1/4"
4 0 8 0 7 2 3
12"
3-1/2"
33"
38"
The vent should be routed to
the fireplace prior to installing
the insert. See the section
"Vent Installation" for details
on vent location.
Use the leveling bolts for
fireplaces with recessed floors
(included with the insert).
Screw them into the baseplate
from below.
Place the insert so the back
edge of the baseplete extends
13-1/4" into the fireplace.
Run the power cord to the side
along the front of the fireplace
(do not route it under the insert).