12) Open the control box. Connect solenoid valve cord  to the CN 106 connectors (red: 19-pin, black: 20-
pin).
* Carefully check the wiring location of the red and black connectors.
13) Install right cover ❷ and secure with screws ❶ .




14) Fit material presser rubber cushion  on clamp
 . (Fit the cushion to the side which has a
shorter distance from the bent section to the
end face.)
15) Insert clamp  into clamp block  and secure
with two setscrews  . At this time, adjust so
that setscrews  are brought to the location of
the slot in the top surface of clamp  .