2.Copier-specific Adjustments
• The subcode varies according to the area where the density is adjusted. Refer to the table below
and set the subcode for the area to be adjusted. The background density will vary, if the low or
middle density area is mainly adjusted. Adjusting the subcode 2 allows you to adjust the high
density area. But it will not affect the background density. Therefore, never change the value for
the high density area.
Subcode
Area where the density is adjusted
0
Low density area
1
Middle density area
After adjusting the gamma curve balance, copy and check the copy image quality.
If further image quality adjustments are still necessary, perform the next procedure.
 Caution after the adjustment
The adjustment may possibly cause text handwritten with a pencil or light text to become illegible on the
copy. Therefore, carefully perform the adjustment, while checking the copy image.
 Remarks
Enter a value within the recommended value range mentioned in the procedures. Otherwise, it may cause
a loss in MFP performance, including degradation in the image quality.