4.e-Filing-specific Adjustments
Scan to Box
(2) When scanning the original, press [Scan Setting] on the Control Panel. Select a lower resolution in
the resolution option.
• "200 (dpi)" is selected from among the resolution options by default. If moiré occurs in a resolution
of 200 dpi, select a lower resolution (150 dpi is recommended.).
After changing the resolution, scan and store the original. Then print and check the print image
quality.
If you do not prefer to decrease a resolution, or if moiré still occurs even in a lower resolution,
perform other procedures.
Scan to Box
(3) When scanning, press [Scan Setting] on the Control Panel. Adjust the sharpness intensity.
• Press [+] on the indicator to increase the sharpness intensity or [-] to decrease it.
• The sharpness intensity is set to the center (±0) by default. If moiré occurs by default, press [-] to
decrease the sharpness intensity.
After adjusting the sharpness intensity, scan and store the original. Then print and check the print
image quality.
With the sharpness intensity set to the minimum, if moiré still occurs, perform other procedures.
Scan to Box
(4) Select [05 ADJUSTMENT MODE]. Change the values for codes [7430 to 7433], [7470], [8335],
[8336], [8354] and [8375] to adjust the sharpness intensity in the scanning functions.
• This adjustment will have an effect only on an image stored in the Full color mode or the Gray
scale mode.
Color mode Original mode [05] code
Text/Photo
Text
Full color
Photo
User Custom
Gray scale
---
Text/Photo
Text
Black
Photo
User Custom
• Setting "0" provides the softest image, while setting "255" provides the sharpest image.
 Caution after the adjustment
When the original containing text and lines is scanned and printed, the adjustment may possibly cause
the blurred text and lines or a blend of undesired colors. Therefore, carefully perform the adjustment,
while checking the scanned-in image or printout.
e-STUDIO2010AC/2510AC/2515AC/3015AC/3515AC/4515AC/5015AC
Recommended value
05-8354
05-8335
05-8336
05-8375
05-7433
Set a value smaller than 128.
05-7430
05-7431
05-7432
05-7470
4-8
Acceptable
value range
0 to 255
© 2018 TOSHIBA TEC CORPORATION All rights reserved
Default
128