To optimize the image quality stability according to the number of output pages in a day or
the type of originals:
By changing the setting value for [08] codes, the image quality control can be started at the desired
timing after the specified number of pages have been output. Referring to the guide below, set the
value appropriately in accordance with the total number of pages output in a day, the number of jobs
frequently performed, or the requested image quality in the user's office.
After changing the setting value, perform the image quality control following the procedure below.
Select [05 ADJUSTMENT MODE]. Select code [2742]. Press the [START] button.
After performing the adjustment, print the image and check its quality.
(A). For standard office use (mainly business documents) (Default)
Code to set
number of
pages
Full IQC
08-2509
Short IQC
08-2497
Printing
08-9199
interrupted
(B). To stabilize the density in continuous copying/printing (when interrupting jobs and starting the
Short Mode at every 50 pages)
Code to set
number of
pages
Full IQC
08-2509
Short IQC
08-2497
Printing
08-9199
interrupted
*7.To start the Short Mode at every 30 pages, set the value to "30" for both 08-2497 and 08-9199.
However, setting a too-short interval will use up too much toner, even though the consumption in
the Short Mode is approximately a quarter of that in the Full Mode.
© 2018 TOSHIBA TEC CORPORATION All rights reserved
1.General Adjustments – Copying, Printing and e-Filing (Output from Box)
Setting value
1000
The control starts after every 1000 pages.
The control starts after 50 pages have been
100
output, or when a job is interrupted after every
500 pages.
500:
e-STUDIO2010AC/
2510AC
400:
e-STUDIO2515AC/
3015AC/3515AC/
4515AC/5015AC
Setting
value *7
1000
The control starts after every 1000 pages.
The control starts when a job is interrupted after every
50
50 pages.
50
e-STUDIO2010AC/2510AC/2515AC/3015AC/3515AC/4515AC/5015AC
1-21
Starting conditions