Default starting conditions
Start-up condition
(1)After the first warming-up in
*3
a day
(2)When recovered from the
toner-empty status
*3
(3)Time left unused
(4)Relative humidity
(5)Accumulated number of
output pages (Full)
(6) Accumulated number of
output pages (Short, Color)
(7) Accumulated number of
output pages (Short, Black)
* 3. The Short Mode is set as a default because the MFP can be recovered from warming-up or the
Sleep Mode in a shorter time. For more stable image quality, switch it to the Full Mode.
* 4. During continuous copying or printing, the control does not start until all jobs are finished.
If the control needs to be started when the specified number of pages has been output, also
change the setting value for code 08-9199 (automatic interruption page number setting for
printing).
* 5. In the Short Mode, the image quality control starts individually for each counter of the Black
Mode and the Color Mode. When the control is performed for the Color Mode, the counter for the
Black Mode is also reset. However, the counter for the Color Mode is not reset when the control is
performed for the Black Mode.
* 6: 0 (Disabled) or 1 (Short) is set for 08-2496. If the equipment is left unused for two hours or
more, the Full mode IQC starts after the end of a job in order to maintain the image quality.
The MFP is installed in a place where the temperature and humidity vary widely:
(a) Set "1" (value  5%R.H.) for code 08-2505 to increase the frequency of image quality control, in
response to a change in humidity.
• Image quality control will be performed, when the relative humidity changes in accordance
with the specified difference from the previous image quality control. If the difference in the
relative humidity exceeds the specified value, image quality control is performed first. Then a
copy or print job will be performed.
Value for 08-2505
1
2
• After setting the value for code 08-2505, forcibly perform image quality control, as follows:
Select [05 ADJUSTMENT MODE]. Select code [2742]. Press the [START] button.
© 2018 TOSHIBA TEC CORPORATION All rights reserved
1.General Adjustments – Copying, Printing and e-Filing (Output from Box)
Full
Short
Switch IQC which starts after the first warming-
()
up in a day. Code: 08-2492
0: Disabled, 1: Short, 2: Full
Switch IQC to start. Code: 08-2496
0: Disabled, 1: Short, 2: Full
()
Set the period of time left unused. Code: 08-
2507, Default: 6 hours
Set the humidity. Code: 08-2505, Default: 10%
RH
Set the number of the output pages. Code: 08-
2509, Default: 1000 pages
Set the number of the output pages. Code: 08-
2497, Default: 100 pages
Difference in relative humidity
5%R.H.
10%R.H. (default)
e-STUDIO2010AC/2510AC/2515AC/3015AC/3515AC/4515AC/5015AC
1-19
Adjustment
-
*6
*4
*4 *5