Led - Bosch Rexroth Nexo Project Planning

Cordless wi-fi nutrunner
Hide thumbs Also See for Rexroth Nexo:
Table of Contents

Advertisement

236/263
Bosch Rexroth AG | Tightening Technology
9.8.12

LED

Settings  LED
Use this menu item to specify the color and intensity of the tightening position illumination at the hand-
held nutrunner for different nutrunner states.
Table 9–88:
Element
Active
Before tightening
During tightening
OK result
LED tab
Description
Tick this check box to enable the following settings for the tightening position
illumination (consisting of an illumination LED and a signal LED) at the hand-
held nutrunner.
Activate this check box in order to enable the tightening position illumination
after the trigger mode and before the tightening process.
– Illumination LED
Intensity: Use the slider control to define the brightness of the illumination
LED.
– Signal LED
RGB: Use the slider to define the color of the signal LED in the RGB color
space (red, green, blue).
– Delay
Sets the delay between releasing the start switch and turning off the tight-
ening position illumination. Values from 0 to 30 seconds are valid.
– Flashing cycle
Sets the flashing cycle of the tightening position illumination.
– Trigger mode
Start switch: The tightening position illumination is turned on by pressing
the start switch.
Activate this check box in order to enable the tightening position illumination
during the tightening process.
– Illumination LED
Intensity: Use the slider control to define the brightness of the illumination
LED.
– Signal LED
RGB: Use the slider to define the color of the signal LED in the RGB color
space (red, green, blue).
– Delay
Sets the delay between releasing the start switch and turning off the tight-
ening position illumination. Values from 0 to 30 seconds are valid.
This setting is only applied for "Play at start switch".
– Flashing cycle
Sets the flashing cycle of the tightening position illumination.
This setting is only applied for "Play at start switch".
Activate this check box in order to enable the tightening position illumination
in an OK tightening process.
– Illumination LED
Intensity: Use the slider control to define the brightness of the illumination
LED.
– Signal LED
RGB: Use the slider to define the color of the signal LED in the RGB color
space (red, green, blue).
– Delay
Sets the delay between reception of the result and turning off the tighten-
ing position illumination. Values from 0 to 30 seconds are valid.
– Flashing cycle
Sets the flashing cycle of the tightening position illumination.
Nexo cordless Wi-Fi nutrunner | 3 608 870 A47/2017-