MID 0020
Reset the OK/NOK counter
Sent by: superordinate computer
This message allows to reset the OK/NOK counter of the Automatic operating mode for the counter value specified
in the command ("Tightening program number" parameter)
Note: The current counter values for all programs will be reset.
Revision: 001
Data field: tightening program number, three ASCII characters (000–999), 3 bytes
Possible responses
Command accepted
Command error
MID 0021
Deactivate the OK/NOK counter
Sent by: superordinate computer
With this message all set values of the OK/NOK counters of the Automatic operating mode can be reset.
Note: All counters of all programs are switched off. The counter values have to be re-enabled via MID 0019.
Revision: 001
Data field: is empty, 0 bytes
Possible responses
Command accepted
7.5.3.5
Job messages
MID 0030
OK counter upload request
Sent by: superordinate computer
All of the configured OK counters (0 to 47) in the tightening system are transferred as a result of this request.
Note: -
Revision: 001
Data field: is empty, 0 bytes
Possible response
Job numbers upload response
MID 0031
OK counter upload response
Sent by: Tightening controller
Transfer of all configured OK counters in the tightening system.
Note: -
Revision:
Data field:
total data field length = (1 + number of configured OK counters) x 2 bytes.
Possible response: none
MID
0005
0004
MID
0005
MID
0031
001
Tightening Technology | Bosch Rexroth AG 109/263
Error no. Comment
01
Invalid data
04
Tightening program not active
Error no. Comment
Error no. Remark