136/263
Bosch Rexroth AG | Tightening Technology
Table 7–29:
Parameter
Torque (T)
Angle (A)
Time stamp
OK/NOK counter status
Data length revision 001
MID 0065 revision 002
Table 7–30:
Parameter
Tightening ID
MID 0065 revision 001
Comments
The value is multiplied by 100 and transferred as a whole number (round-
ed to 2 decimals).
The value consists of six ASCII characters.
ID
Value range
Presetting
Example:
Torque (T)
Value
The value is output in degrees.
The value consists of five ASCII characters.
ID
Value range
Presetting
Example:
Angle (A)
Value
Date and time of tightening.
The value consists of 19 ASCII characters in YYYY-MM-DD:HH:MM:SS
format.
ID
Value range
Presetting
Example:
Time stamp
Value
Status of the OK/NOK counter.
– 0: unless 1 or 2
– 1: Ch x.y CntOK = 1
– 2: OK/NOK counter not used (not configured)
The value consists of one ASCII character.
ID
Value range
Presetting
Example:
OK/NOK counter
status
Value
MID 0065 revision 002
Comments
With an activated OP, consecutive number for each tightening result.
The value consists of ten ASCII characters.
ID
Value range
Presetting
Example:
Tightening ID
Value
08
000000 – 999999
-
20.00
002000
09
00000 – 99999
-
60
00060
10
0 – 9, - and :
-
1/12/2009:2:43:57 PM
1/12/2009:2:43:57 PM
11
0 – 2
-
OK/NOK counter not used
2
01
0000000000 – 9999999999
-
123456
0000123456
Bytes
2
6
2
5
2
19
2
1
98
Bytes
2
10

Advertisement