108/263
Bosch Rexroth AG | Tightening Technology
MID 0019
Make the presetting for OK/NOK counter
Sent by: superordinate computer
This message sets the presetting for the OK counter and the NOK counter of the Automatic operating mode (pa-
rameter "OK counter limit") for the counter value specified in the command ("Tightening program number" parameter)
Note: -
Revision:
Data field: Data 7 bytes
Possible responses
Command accepted
Command error
MID 0019 revision 001
Table 7–15:
Parameter
Tightening program number
OK counter value
Data length revision 001
MID 0019 revision 002
Table 7–16:
Parameter
This revision includes the information from revision 001 and the following additional information:
NOK counter value
Data length revision 002
001, 002
MID
0005
0004
MID 0019 revision 001
Comments
The value consists of 3 ASCII characters.
ID
Value range
Presetting
Example:
Tightening program number
Value
The value consists of 2 ASCII characters.
ID
Value range
Presetting
Example:
OK counter value
Value
MID 0019 revision 002
Comments
The value consists of 2 ASCII characters.
ID
Value range
Presetting
Example:
NOK counter value
Value
Error no. Comment
01
Invalid data
-
000 – 999
-
3
003
-
00 – 99
-
9
09
-
00 – 99
-
5
05
Bytes
3
2
5
Bytes
2
7