Bosch Rexroth Nexo Project Planning page 118

Cordless wi-fi nutrunner
Hide thumbs Also See for Rexroth Nexo:
Table of Contents

Advertisement

118/263
Bosch Rexroth AG | Tightening Technology
Table 7–23:
Parameter
Channel ID
Controller name
ID code
Job number
Tightening program number
OK counter limit
MID 0061 revision 001
Comments
The first two characters of a channel name are used as channel ID. A
channel name consists of the channel ID and the name of the controller,
both of which are separated by a space.
The value consists of two ASCII characters.
ID
Value range
Presetting
Example:
Channel ID
Value
The second part of the channel name is used as the controller name.
The value consists of 25 ASCII characters.
ID
Value range
Presetting
Example:
Controller name
Value
Contains the first 25 bytes of the ID code.
The value consists of 25 ASCII characters.
ID
Value range
Presetting
Example:
ID code
Value
Number of the selected OK/NOK counter
The value consists of two ASCII characters.
ID
Value range
Presetting
Example:
Job number
Value
Number of the current tightening program.
The value consists of three ASCII characters.
ID
Value range
Presetting
Example:
Tightening pro-
gram number
Value
OK counter presetting
The value consists of four ASCII characters.
ID
Value range
Presetting
Example:
OK counter limit
Value
02
01 – 20
01
04 tightening channel
04
03
0x20 – 0x7F
***
04 tightening channel
Tightening channel
04
0x20 – 0x7F
-
123456
123456
05
01 – 99
-
2
02
06
000 – 999
-
5
005
07
0000 – 9999
-
12
0012
Bytes
2
2
2
25
2
25
2
2
2
3
2
4

Advertisement

Table of Contents
loading