MID 0041 revision 002-1
Table 7–19:
Parameter
This revision includes the information from revision 001 and the following additional information:
MCE factor
Date of the last check
Cycles since maintenance
Tool type
Motor size
Open end data
MID 0041 revision 002-1
Comments
The value is multiplied by 1000 and transferred as a whole number (round-
ed to 3 decimals).
The value consists of 4 ASCII characters.
ID
Value range
Example:
MCE factor
Value
Date output in YYYY-MM-DD:HH:MM:SS format.
The value consists of 19 ASCII characters.
ID
Value range
Presetting
Example:
Date of the last check
Value
Calculated from the cycles during the last maintenance and the current
number of cycles
The value consists of ten ASCII characters.
ID
Value range
Presetting
Example:
Cycles since maintenance
Value
The value consists of two ASCII characters.
ID
Value range
Value
Fixed value 01
The value consists of two ASCII characters.
ID
Value range
Presetting
Example (tightening spindle):
Motor size
Value
The value consists of three ASCII characters.
ID
Fixed value
05
500 - 2000
1.0001
1000
06
0 – 9, - and :
-
1/12/2009:2:43:57 PM
1/12/2009:2:43:57 PM
07
0000000000 – 9999999999
-
123412
0000123412
08
00 – 99
Nexo: 05
09
00 – 99
-
03
03
10
000
Bytes
2
4
2
19
2
10
2
2
2
2
2
3