144/263
Bosch Rexroth AG | Tightening Technology
MID 0073
Cancel system errors subscription
Sent by: superordinate computer
Cancel system errors subscription
Note: -
Revision: 001
Data field: is empty, 0 bytes
Possible responses
Command accepted
Command error
MID 0074
System error in tightening controller acknowledged
Sent by: Tightening controller
The tightening controller sends this message to inform the superior computer that an error has been acknowledged.
Note: -
Revision: 001
Data field: Error number, 4 bytes
Possible response
Acknowledgement System error in tight-
ening controller acknowledged
MID 0075
Acknowledgement System error in tightening controller acknowledged
Sent by: superordinate computer
Acknowledgment for MID 0074
Note: -
Revision: 001
Data field: is empty, 0 bytes
Possible response: none
MID 0076
System error status
Sent by: Tightening controller
The system error status is sent after a subscription for system errors from the tightening controller has been accepted.
Note: The system error status informs the superior computer that a system error is currently active in the connected
controller. Exactly one system error status message is sent for each active system error in the connected controller.
Revision:
Data field: Data 36 bytes
Possible response
System error status acknowledgement
MID
0005
0004
MID
0075
001
MID
0077
Error no. Comment
–
12
Activation of system errors not available
Error no. Remark
–