Chapter 8
Servicing the Device

Removing and Installing a Power Supply (IDP 200, 600, and 1100 Only)

To Remove a Power Supply or Blank

This chapter describes the service and maintenance of various components in your
IDP Sensors.
Removing and Installing a Power Supply (IDP 200, 600, and 1100 Only)
Removing and Installing a SCSI Hard Drive (IDP 600 and 1100 Only) on page 38
Connecting and Disconnecting Fiber Cables (IDP 600F and 1100F Only) on
page 42
The IDP 200 has one power supply and an empty bay for a second power supply.
The IDP 600 and 1100 have two power supplies.
You can add a second power supply to an IDP 200 while the device is running.
Redundant power supplies are available for purchase from Juniper Networks.
If a device has two power supplies, one of the power supplies may be hot swapped
while the device is running.
Contact Juniper Networks if you want to have a spare power supply on hand.
If the device has two power supplies, then one of them can be removed without
affecting the performance of the device. If the device has only one power supply,
shut down the device before removing the power supply.
The IDP 200 can use two power supplies, but ships with one. The other power
supply bay is covered with a blank. If you want to install a power supply in the
second bay, first remove the blank using this procedure.
1. Go to the back of the device.
2. Identify the power supply or blank you want to remove.
Removing and Installing a Power Supply (IDP 200, 600, and 1100 Only)