Oscillation
11.2 Oscillation controlled by synchronized actions (OSCILL)
11.2
Oscillation controlled by synchronized actions (OSCILL)
11.2
Function
With this mode of oscillation, an infeed motion may only be executed at the reversal points or
within defined reversal areas.
Depending on requirements, the oscillation movement can be
● continued or
● stopped until the infeed has finished executing.
Syntax
1. Define parameters for oscillation
2. Define motion-synchronous actions
3. Assign axes, define infeed
Meaning
OSP1[<oscillating
axis>]=
OSP2[<oscillating
axis>]=
OST1[<oscillating
axis>]=
OST2[<oscillating
axis>]=
FA[<oscillating axis>]=
OSCTRL[<oscillating
axis>]=
OSNSC[<oscillating
axis>]=
OSE[<oscillating axis>]=
WAITP(<oscillating
axis>)
738
Position of reversal point 1
Position of reversal point 2
Stopping time at reversal point 1 in seconds
Stopping time at reversal point 2 in seconds
Feed for oscillating axis
Set or reset options
Number of sparking-out strokes
end position
Enable axis for oscillation
Programming Manual, 06/2009, 6FC5398-2BP20-0BA0