<init_time>:
<init_value>:
Example
Redefinitions of system variable $TC_DPC1 in the data block for machine manufacturers
Program code
%_N_MGUD_DEF
$PATH=/_N_DEF_DIR
REDEF $TC_DPC1 APWB 2 APWP 3
REDEF $TC_DPC1 PHU 21
REDEF $TC_DPC1 LLI 0 ULI 200
REDEF $TC_DPC1 INIPO (100, 101, 102, 103)
; Description
;
Write access right: OPI = protection level 2, part program = protection level 3
;
Note
;
When using ACCESS files the redefinition of access rights has to be moved from
;
_N_MGUD_DEF to _N_MACCESS_DEF.
; Physical unit = [ % ]
; Limit values: lower = 0, upper = 200
; The array variable is initialized with the 4 values at POWER ON.
M30
Job Planning
Programming Manual, 06/2009, 6FC5398-2BP20-0BA0
Point in time at which the variable is reinitialized
POWER ON
INIPO:
End of main program, NC reset or POWER ON
INIRE:
NewConfig or end of main program, NC reset or
INICF:
POWER ON
End of main program, NC reset following local
PRLOC:
change or POWER ON
See "Attribute: Initialization value (Page 34)"
Initialization value
When redefining the initialization value, an initialization time always
has to be specified also (see <init_time>).
See "Attribute: Initialization value (Page 34)"
For the initialization of array variables:
See "Definition and initialization of array variables (DEF, SET, REP)
(Page 48)"
Note
Cannot be redefined for:
• System variables, with the exception of setting data
; GUD block: Machine manufacturer
Flexible NC programming
1.1 Variables