Siemens SINUMERIK 840D sl Programming Manual page 35

Job planning
Hide thumbs Also See for SINUMERIK 840D sl:
Table of Contents

Advertisement

Reinitialization time
During redefinition a point in time can be specified at which the variable should be
reinitialized, i.e. reset to the initialization value.
● INIPO (POWER ON)
● INIRE (reset)
● INICF (NewConfig)
● PRLOC (program-local change)
Table 1- 1
Number
Job Planning
Programming Manual, 06/2009, 6FC5398-2BP20-0BA0
The variable is reinitialized at POWER ON.
The variable is reinitialized on NC reset, mode group reset, at the end of the part program
(M02/M30) or at POWER ON.
The variable is reinitialized on a NewConf request via the HMI, with part program
command NEWCONFIG or on an NC reset, mode group reset, at the end of the part
program (M02/M30) or at POWER ON.
The variable is only reinitialized on an NC reset, mode group reset or at the end of the
part program (M02/M30) if it has changed during the current part program.
The PRLOC attribute may only be changed in conjunction with programmable setting data
(see the table below).
Programmable setting data
Identifier
42000
$SC_THREAD_START_ANGLE
42010
$SC_THREAD_RAMP_DISP
42400
$SA_PUNCH_DWELLTIME
42800
$SA_SPIND_ASSIGN_TAB
43210
$SA_SPIND_MIN_VELO_G25
43220
$SA_SPIND_MAX_VELO_G26
43230
$SA_SPIND_MAX_VELO_LIMS
43300
$SA_ASSIGN_FEED_PER_REV_SOURCE
43420
$SA_WORKAREA_LIMIT_PLUS
43430
$SA_WORKAREA_LIMIT_MINUS
43510
$SA_FIXED_STOP_TORQUE
43520
$SA_FIXED_STOP_WINDOW
Flexible NC programming
1.1 Variables
G command
1)
SF
DITS/DITE
PDELAYON
SETMS
G25
G26
LIMS
FPRAON
G26
G25
FXST
FXSW
35