Comdial DX-80 Technical Manual page 68

Hide thumbs Also See for DX-80:
Table of Contents

Advertisement

Installing the DX-80
4. Locate the CPM and "NORMAL/COLD START" option strap on the CPM (J11).
5. Move this strap to the "COLD START" position and allow it to remain in this position for 5
seconds. Note: New systems are shipped with this strap in the "COLD START" position, so if
you are installing a new system you can skip this step.
This procedure overwrites all customized customer programming. If
you want to maintain customized programming, be sure to back up the
custom database prior to performing the cold start. For more details, refer to the
6. Move the strap to the "NORMAL" position.
Comdial ships the DX-80 with the option strap in the COLD START
position to preserve the battery while the system is in transit.
However, you MUST move this strap to NORMAL for the DX-80 to begin normal
operation. The system specifically monitors the position of this strap and shuts down
7. Install all optional expansion modules (COM4, DPM8, APM4) inside the KSU as required.
68
CAUTION
DX-80 Technical Manual, Volume II, Programming.
CAUTION
operation if it remains in the COLD START position.
Comdial
J11 Normal/Cold
Start Option Strap
October, '03