Maintenance and Trouble Shooting
Symptom(s)
(Continued)
Programming lost
Digital
or changed.
Executive
Telephone
display.

3.3 Maintenance Utilities

The DX-80 includes a versatile maintenance utility that you access through PC-DBA. A technician
with PC skills can easily use the maintenance function to obtain various data and information about the
DX-80 and all connected components.
The DX-80 system allows you to administer system database parameters via an IBM
Personal Computer. The use of a PC has distinct advantages over programming the system via the
digital telephone, including: specific database archiving (via save function), remote programming, out-
board programming (program the system template into the PC memory then send it to the DX-80 when
ready). The PC program that interfaces with the DX-80 system is PC-DBA (PC-Database Adminis-
tration). Note: PC-DBA is a DOS-based programming utility.
PC-DBA requires the following resources in the PC environment:
• PC running DOS (PC-DBA can be run in a DOS Window but performance can be impacted by
®
other Windows
modules. We do not warranty or guarantee any level of performance in the
Windows environment.)
• 640k minimum RAM
• 386 minimum microprocessor
• 2 megabytes minimum space on the hard disk
76
Diagnostic
Cause(s)
Aid
Intended
programming
change.
PC-DBA
programming
changes Send
All operation.
Bad Memory
battery
Comdial
Action
Check with system administrator for incidental
changes made.
When using PC-DBA to make customer
database changes you must take special
precaution not to overwrite existing data with
residual PC-DBA working directory values.
When using PC-DBA to update any database,
it is highly recommended to perform the
function Receive All prior to making any
specific database changes to assure that the
working directory database matches the
database in use at the customer site.
If power fluctuations occur and the memory
battery backup battery is low or bad, the
customer database is susceptible to being
defaulted (factory settings loaded) whenever a
power interruption occurs. If this occurs
change the standard (photo-cell type) lithium
battery.
®