DX-80 Installation & Maintenance
When you are finished with the KSU wiring, you can individually isolate each port of the DX-80
system for independent maintenance needs. Terminate the wiring in place onto a 66M1-50 – connector
block. Extend ports from this connector block to station cables using standard jumper wire.

2.5.2 NO MDF

Since the Comdial DX-80 is equipped with RJ-11 interfaces for all port connections, it is possible to
route station cables into the KSU directly without use of 66M1-50 connector blocks. Using quality
modular connectors and crimping tool, connect each terminal cable directly to the port required.
Comdial does not recommend this method of installation, although it is initially convenient and less
expensive, due to the inherent lack of serviceability.
Regardless of the method used, route the station / MDF cables out of the KSU through the opening at
the lower left of the KSU housing. A cable restraint clamp is provided which you can use to secure
cables exiting the KSU.
cable restraint
clamp
October, '03
Comdial
45