[Pr. PB23_Low-pass filter selection (VFBF)]

Initial value
00001000h
[Pr. PB23.0_Shaft resonance suppression filter selection]
Initial value
0h
Select the shaft resonance suppression filter.
0: Automatic setting
1: Manual setting
2: Disabled
When [Pr. PB49.0 Machine resonance suppression filter 4 selection] is set to "1" (enabled), the shaft resonance suppression
filter cannot be used.
[Pr. PB23.1_Low-pass filter selection]
Initial value
0h
Select the low-pass filter.
0: Automatic setting
1: Manual setting
2: Disabled
When "5" (quick tuning mode) is selected in [Pr. PA08.0 Gain adjustment mode selection], this servo parameter is set to "1"
(manual setting).
[Pr. PB23.3_Shaft resonance suppression filter 2 selection]
Initial value
1h
0: Disabled
1: Automatic setting
Setting range
Refer to the relevant detail No.
Setting range
Refer to the text
Setting range
Refer to the text
Setting range
Refer to the text
1.3 Gain/filter setting servo parameters group ([Pr. PB_ _ ])
Ver.
Refer to the relevant detail No.
Ver.
A4
Ver.
A4
Ver.
A4
1 SERVO PARAMETER DETAILS