[Pr. Pb50_Machine Resonance Suppression Filter 5 (Nh5)]; [Pr. Pb51_Notch Shape Selection 5 (Nhq5)] - Mitsubishi Electric Melservo-Jet MR-JET-G User Manual

Ac servo system, parameters
Hide thumbs Also See for Melservo-Jet MR-JET-G:
Table of Contents

Advertisement

[Pr. PB50_Machine resonance suppression filter 5 (NH5)]

Initial value
4500 [Hz]
Set the notch frequency of the machine resonance suppression filter 5.
When [Pr. PB51.0 Machine resonance suppression filter 5 selection] is set to "1" (enabled), set the notch frequency with this
servo parameter.

[Pr. PB51_Notch shape selection 5 (NHQ5)]

Initial value
00000000h
Set forms of the machine resonance suppression filter 5.
When [Pr. PA08.0 Gain adjustment mode selection] is set to "5" (quick tuning mode), the setting value of this servo parameter
reflects the adjustment result of quick tuning.
When [Pr. PE41.0 Robust filter selection] is set to "1" (enabled), machine resonance suppression filter 5 cannot be used.
[Pr. PB51.0_Machine resonance suppression filter 5 selection]
Initial value
0h
0: Disabled
1: Enabled
[Pr. PB51.1_Notch depth selection]
Initial value
0h
0: -40 dB
1: -14 dB
2: -8 dB
3: -4 dB
[Pr. PB51.2_Notch width selection]
Initial value
0h
0: α = 2
1: α = 3
2: α = 4
3: α = 5
Setting range
10 to 9000
Setting range
Refer to the relevant detail No.
Setting range
Refer to the text
Setting range
Refer to the text
Setting range
Refer to the text
1.3 Gain/filter setting servo parameters group ([Pr. PB_ _ ])
Ver.
A4
Ver.
Refer to the relevant detail No.
Ver.
A4
Ver.
A4
Ver.
A4
1 SERVO PARAMETER DETAILS
1
47

Advertisement

Table of Contents
loading

Table of Contents