[Pr. PB23_Low-pass filter selection (VFBF)]

Initial value
00001000h
[Pr. PB23.0_Shaft resonance suppression filter selection]
Initial value
0h
Select the shaft resonance suppression filter.
0: Automatic setting
1: Manual setting
2: Disabled
When [Pr. PB49.0 Machine resonance suppression filter 4 selection] is set to "1" (enabled), the shaft resonance suppression
filter cannot be used.
[Pr. PB23.1_Low-pass filter selection]
Initial value
0h
Select the low-pass filter.
0: Automatic setting
1: Manual setting
2: Disabled
When "5" (quick tuning mode) is selected in [Pr. PA08.0 Gain adjustment mode selection], this servo parameter is set to "1"
(manual setting).
[Pr. PB23.3_Shaft resonance suppression filter 2 selection]
Initial value
1h
0: Disabled
1: Automatic setting
Setting range
Refer to the relevant detail No.
Setting range
Refer to the text
Setting range
Refer to the text
Setting range
Refer to the text
Setting method
Each axis
Ver.
C4
Ver.
C4
Ver.
C4
1 SERVO PARAMETER DETAILS