Table 22: Clock controller commands in LD 60
in LD 60.

Clock controller commands (LD 60)

Table 22: Clock controller commands in LD 60
Command
DIS CC x
DSCK L
DSYL L
ENL CC x
ENYL L
EREF
MREF
SSCK x
SWCK
TRCK xxx
80
ISDN Primary Rate Interface Maintenance
Disable specified system clock controller x (0 or 1).
Disables the clock for loop L.
Disables remote alarm processing for loop L.
Enable specified system clock controller x (0 or 1).
Enables remote alarm processing for loop L.
Enables automatic switching and recovery of primary and secondary
reference clocks when loops associated with these clocks are
automatically enabled.
Disables automatic switching and recovery of the primary and secondary
reference clocks when loops associated with these clocks are
automatically disabled or in local alarm.
Provides status of system clock x (0 or 1). Indicates the active controller
as well as active primary or secondary reference-clock source or free
run.
Switches the system clock from the active to the standby clock. The
reference-clock source remains unchanged.
Set clock-controller tracking where xxx represents one of the following
mnemonics:
PCKtrack primary clock
SCLKtrack secondary clock
FRUNfree-run mode
Comments? infodev@avaya.com