Avaya CS 1000 Maintenance Manual page 73

Isdn primary rate interface
Hide thumbs Also See for CS 1000:
Table of Contents

Advertisement

The PLOG counters are cleared after:
• the PLOG is printed, or
• the DCHI card is enabled
Note:
When a protocol counter overflows, the PLOG is printed automatically and the counters are
cleared.
When the PLOG has non-zero counters, check the PRI status and alarms as shown in
Checking the PLOG status
PLOG.
Checking the PLOG status
1. Check the contents of the PLOG using the following:
2. If there are PRI bit rate or frame errors, assume there is a PRI problem.
3. If there is no problem with the PRI but there are a large number of protocol errors,
Table 20: Protocol log
Format
DCH : XX MAINT CONFIRM TIME: <time of day>
COUNTERVALUE
Protocol counters
1
count of missing PRI handshakes
2
count of peer-initiated re-establishment link
3
count of unsuccessful retransmit N200 of SABME
4
count of unsuccessful retransmit N200 of DISC
5
count of N(R) errors
6
count of information fields with length greater than N201
7
count of undefined frames
8
count of information fields that are not allowed to contain information
9
count of FRMR frames received from the far end
10
count of CRC error frames received from the far end
11
count of REJ frames received from the far end
ISDN Primary Rate Interface Maintenance
on page 73. See
LD 96 PLOG DCH x
Response: DCH : XX MAINT CONFIRM TIME: <time of day> COUNTERVALUE 1:
12 12: 8 20: 15 N: XX
report a protocol problem.
Table 20: Protocol log
Protocol log (PLOG)
on page 73 for the
November 2011
73