Table 82: Clock controller commands
Command
DIS CC X
ENL CC X
SSCK X
TRCK XXX N
NTAK79/NTBK50 power on self-test
When power is applied to the NTAK79/NTBK50 2.0 Mb PRI circuit card, the card performs a
power-on self-test. The self-tests verify the operation of most of the on-board hardware.
If all the self-tests pass, the upper five LEDs blink simultaneously three times. If any of the self-
tests fail, the LEDs do not blink. Only the OOS LED illuminates. The corresponding error code
is then printed on the TTY.
Self-test error codes
for the NTAK79/NTBK50 2.0 Mb PRI. These codes can be returned on card power-up in the
form "DTA105 L X" (where X is the failure code), or during a self-test procedure in LD 60 as
"DTI009 L X" (where X is the error code).
Failure codes 1-14 are hardware failures on the NTAK79/NTBK50 card. Codes 15-16 might
be due to carrier span problems or lack of loopback activation at the far end.
Table 83: Self-test error codes
Failure code
0
1
2
3
4
5
6
7
8
9
ISDN Primary Rate Interface Maintenance
Disable clock controller.
Enable clock controller.
Status of clock controller.
Set clock controller tracking where XXX can be: PCK — track
primary clock reference source SCLK — track secondary
clock reference source FRUN — free run mode
Table 83: Self-test error codes
Self-test passed.
Self-test general failure.
LCAs failed to program correctly.
8031 code checksum failure.
8031 internal RAM failure.
8031 external RAM failure.
PAD RAM failure.
AO7 signaling interface failure.
UART (card LAN) failure.
CEPT transceiver failure.
Action
on page 161 lists the self-test failure codes
Associated error
System PRI maintenance tools