Step
2
If any other LEDs are lit, go to PRI fault
clearing.
3
Test all PRIs using:
LD 60
DISL loop SLFT L
4
Enable all PRIs using:
LD 60
ENLL L
5
Enable the D-channel(s) using:
LD 96
ENL DCH N
(N is the I/O port number)
6
Perform a PRI status check.
EST DCH N
(N is the I/O port number)
ISDN Primary Rate Interface Maintenance
Action
Note:
If the status check response is RLS,
establish the link at this point by
entering the command:
Response
SLFT OK
PRI000
Correct version ID
DTA005
remote alarm
DTA007
remote alarm cleared
DTA023
(provided the far end is
DCH1010
up)
PRI loop is up
D-channel is disabled
DCH EST Time and Date
D-channel is established (provided far-
end D-channel is OK).
If you do not get the DCH EST response,
see the note at step 6.
PRI startup