2.0 Mb PRI maintenance
DDCH commands
Downloadable D-channel commands are found in LD 96.
page 160 provides a quick-reference list of D-channel commands with minor modification.
Table 81: DDCH commands
Command
DIS MSDL X (ALL)
ENL MSDL X (FDL,
ALL)
RST MSDL X
STAT MSDL X (X (full)) Get MSDL status X, or a "FULL STATUS".
SLFT MSDL X
DIS LLB X
DIS RLB X
DIS TEST X
ENL LLB X
ENL RLB X
ENL TEST X
PCON DCH X
PMES DCH X
PTRF DCH X
TEST LLB X
TEST RLB X
Note:
"X" represents the D-channel device number.
D-channel status and error conditions are reported as DCH messages. These messages can
be found in the Avaya Software Input Output Reference - Maintenance (NN43001-711).
Clock controller commands
Clock controller (CC) commands are accessed in LD 60.
commands
160
ISDN Primary Rate Interface Maintenance
Disable DCHI card X.
Enable DCHI card X, with or without Force Download.
Reset MSDL card X.
Execute a self-test on MSDL card X.
Disable local loop back on MSDL DCH X.
Disable remote loop back on MSDL DCH X.
Disable Test mode on MSDL DCH X.
Enable local loop on MSDL DCH X.
Enable remote loop on MSDL DCH X.
Enable Test mode on MSDL DCH X.
Print configuration parameters on MSDL DCH X.
Print incoming layer 3 messages on MSDL DCH X.
Print traffic report on MSDL DCHX.
Start local loop back test on MSDL DCH X.
Start remote loop back test on MSDL DCH X.
on page 161 provides a quick-reference list of clock controller commands.
Comments? infodev@avaya.com
Table 81: DDCH commands
Action
Table 82: Clock controller
on
November 2011